Transformers & Control Gear |
||||
|
12V DISPLAY LIGHTING "YT Dimmable" Electronic Transformers |
||||
| YT105 | YT150 | YT250 | ||
|
Input Voltage |
230V a.c. +/- 10% ; 50Hz |
230V a.c. +/- 10% ; 50Hz |
230V a.c. +/- 10% ; 50Hz |
|
|
Input Current |
0.46A FOR 105W |
0.65A for 150W |
1.1A for 250W |
|
|
Power Range |
105Va: 0 - 105W |
150Va: 0 - 150W |
250Va: 0 - 250W |
|
|
Output Voltage |
11.5V Max. 9.3A |
11.5V Max. 12.5A |
11.5V Max. 22A |
|
|
Power Factor |
> 0.99 |
> 0.99 |
> 0.99 |
|
|
Ambient Temperature Range |
0 - 40ºC |
0 - 40ºC |
0 - 40ºC |
|
|
Insulation Class |
II |
II |
II |
|
|
Quantity of Input Terminals |
1 Pair |
2 Pairs |
2 Pairs |
|
|
Quantity of Output Terminals |
2 Pairs |
3 Pairs |
3 Pairs |
|
|
Weight |
140g |
230g |
250g |
|
|
FEATURES "Soft start" which gently brings the lamps up to full brightness when you switch on. This feature will also extend the lamp life. "Trouble free dimming" using VARILIGHT intelligent dimmers for low voltage lighting (including touch and touch/remote versions) which are specifically designed for low voltage lighting as well as normal mains lighting. Up to 10 DISPLAY LIGHTING YT Transformers may be used per VARILIGHT intelligent dimmer as long as the total load does not exceed the maximum rating of the transformer. To calculate the total load for dimming, add the wattages of all the lamps you intend to dim and choose a dimmer to suit. INSTALLATION ADVICE Each YT Transformer should be located in a well ventilated position. It is important that the cable lengths on the output side of the transformer are neither too short or too long (optimum length - 30cm). If the transformer is fitted too close to the luminaire (nearer than 25cm), heat from the lamp could affect the functioning of the transformer. If the cable is too long, a "voltage drop" may result and it will cause the lamp to be less bright. The longer the cable on the output side, the thicker the cable needs to be to reduce this effect. Should any defect occur on the transformers above within 12 months of purchase we will replace or repair the defective unit free of charge provided that: a. the unit has been correctly fitted in accordance with the instructions. b. the transformer has not been tampered with or taken apart. c. the transformer is securely packed and safely returned. |
||||
|
12V DISPLAY LIGHTING "PUMA" Electronic Transformers |
||||
| DL60 | DL105 | DL150 | ||
|
Input Voltage |
230V a.c. +/- 10% ; 50Hz |
230V a.c. +/- 10% ; 50Hz |
230V a.c. +/- 10% ; 50Hz |
|
|
Input Current |
0.26A for 60W |
0.46A FOR 105W |
0.62A for 150W |
|
|
Power Range |
60Va: 20W - 60W |
105Va: 20W - 105W |
150Va: 30W - 150W |
|
|
Output Voltage |
11.5V Max. |
11.5V Max. |
11.5V Max. 12.5A |
|
|
Power Factor |
> 0.75 |
> 0.75 |
> 0.99 |
|
|
Ambient Temperature Range |
0 - 50ºC |
0 - 40ºC |
0 - 40ºC |
|
|
Insulation Class |
II |
II |
II |
|
|
Quantity of Input Terminals |
2 Pairs |
2 Pairs |
2 Pairs |
|
|
Quantity of Output Terminals |
2 Pairs |
2 Pairs |
3 Pairs |
|
|
Dimensions |
133 x 39 x 27 | 133 x 39 x 27 | 190 x 48 x 39 | |
|
INSTALLATION ADVICE Each PUMA Transformer should be located in a well ventilated position. It is important that the cable lengths on the output side of the transformer are neither too short or too long (optimum length - 30cm). If the transformer is fitted too close to the luminaire (nearer than 25cm), heat from the lamp could affect the functioning of the transformer. If the cable is too long, a "voltage drop" may result and it will cause the lamp to be less bright. The longer the cable on the output side, the thicker the cable needs to be to reduce this effect. Should any defect occur on the transformers above within 12 months of purchase we will replace or repair the defective unit free of charge provided that: a. the unit has been correctly fitted in accordance with the instructions. b. the transformer has not been tampered with or taken apart. c. the transformer is securely packed and safely returned. |
||||
|
Type |
Description | Rating | Dimensions (mm) | Order Code |
| 240V - 12V Boxed & Multi-Fused Tungsten Halogen Transformers. |
100Va Boxed & Multi Fused Transformer |
2 x 20, 35 or 50W (5A) | 220 x 160 x 70 | DLB100/2 |
|
150Va Boxed & Multi Fused Transformer |
3 x 20, 35 or 50W (5A) | 220 x 160 x 70 | DLB150/3 | |
|
200Va Boxed & Multi Fused Transformer |
4 x 20, 35 or 50W (5A) | 220 x 160 x 70 | DLB200/4 | |
|
250Va Boxed & Multi Fused Transformer |
5 x 20, 35 or 50W (5A) | 280 x 180 x 70 | DLB250/5 | |
|
300Va Boxed & Multi Fused Transformer |
6 x 20, 35 or 50W (5A) | 280 x 180 x 70 | DLB300/6 | |
|
400Va Boxed & Multi Fused Transformer * |
8 x 20, 35 or 50W (5A) | 280 x 180 x 70 | DLB400/8 | |
|
500Va Boxed & Multi Fused Transformer * |
10 x 20, 35 or 50W (5A) | 280 x 180 x 70 | DLB500/20 | |
|
IP66 rated enclosures also available with the exception of those marked *, please ask our sales dept for details, 0161929 3355. |
||||
|
Type |
Description | Rating | Dimensions (mm) | Order Code |
| 240V - 12V Boxed & Track Fused Tungsten Halogen Transformers. |
100Va Boxed & Single Fused Track Transformer |
100W | 220 x 160 x 70 | DLB100 |
|
150Va Boxed & Single Fused Track Transformer |
150W | 220 x 160 x 70 | DLB150 | |
|
200Va Boxed & Single Fused Track Transformer |
200W | 220 x 160 x 70 | DLB200 | |
|
250Va Boxed & Single Fused Track Transformer |
250W | 220 x 160 x 70 | DLB250 | |
|
300Va Boxed & Single Fused Track Transformer |
300W | 220 x 160 x 70 | DLB300 | |
|
400Va Boxed & Single Fused Track Transformer |
400W | 350 x 180 x 70 | DLB400 | |
|
500Va Boxed & Single Fused Track Transformer |
500W | 350 x 180 x 70 | DLB500 | |
|
IP66 rated enclosures also available, please ask our sales dept for details, 0161929 3355. |
||||
|
Type |
Description | Rating | Dimensions (mm) | Order Code |
| Metal Halide/HQI Gear Boxes |
70W HQI Single Fused Gear Box |
70W | 290 x 114 x 66 | DLHQI-70 |
|
150W HQI Single Fused Gear Box |
150W | 290 x 114 x 66 | DLHQI-150 | |
|
Type |
Description | Rating | Dimensions (mm) | Order Code |
|
T5 Switch Start Gear Trays
|
Single 2W, 4W, 6W or 8W Switch Start Gear Tray |
1 x 2, 4, 6 or 8W |
265 x 35 |
DL-1468 |
|
Double 2W, 4W, 6W or 8W Switch Start Gear Tray |
2 x 2, 4, 6 or 8W |
265 x 35 |
DL-2468 |
|
|
Single 13W Switch Start Gear Tray |
1 x 13W |
265 x 35 |
DL-113 |
|
|
Double 13W Switch Start Gear Tray |
2 x 13W |
376 x 50 |
DL-213 |
|
|
Switch Start Gear Trays also available in ventilated Gear Box versions, please ask our sales dept for details, 0161 929 3355. |
||||
|
Type |
Description | Rating | Dimensions (mm) | Order Code |
| TL5 Electronic High Frequency Gear Trays |
Single 14W Electronic Gear Tray |
1 x 14W |
376 x 50 |
DLHF-114 |
|
Double 14W Electronic Gear Tray |
2 x 14W |
376 x 50 |
DLHF-214 |
|
|
Single 21W Electronic Gear Tray |
1 x 21W |
376 x 50 |
DLHF-121 |
|
|
Double 21W Electronic Gear Tray |
2 x 21W |
480 x 50 |
DLHF-221 |
|
|
Single 28W Electronic Gear Tray |
1 x 28W |
376 x 50 |
DLHF-128 |
|
|
Double 28W Electronic Gear Tray |
2 x 28W |
480 x 50 |
DLHF-228 |
|
|
Single 35W Electronic Gear Tray |
1 x 35W |
376 x 50 |
DLHF-135 |
|
|
Double 35W Electronic Gear Tray |
2 x 35W |
480 x 50 |
DLHF-235 |
|
|
Electronic Gear Trays also available in ventilated Gear Box versions, please ask our sales dept for details, 0161 929 3355. |
||||