Electronic Transformers by Display Lighting Ltd

 

12V "YT Dimmable" Electronic Transformers

  • YT transformers feature "Soft start" which gently brings the lamps up to full brightness when you switch on, this feature will also extend the lamp life.

  • Trouble free dimming" using VARILIGHT intelligent dimmers for low voltage lighting (including touch and touch/remote versions) which are specifically designed for low voltage lighting as well as normal mains lighting.

  • Up to 10 DISPLAY LIGHTING YT Transformers may be used per VARILIGHT intelligent dimmer as long as the total load does not exceed the maximum rating of the transformer.

  • To calculate the total load for dimming, add the wattages of all the lamps you intend to dim and choose a dimmer to suit.

YT050

 

YT070

Input Voltage

Input Current

Power Range

Output Voltage

Power Factor

Ambient Temperature Range

Insulation Class

Quantity of Input Terminals

Quantity of Output Terminals

Weight

Dimensions

230V a.c. +/- 10% ; 50Hz

0.A for 50W

50Va: 0 - 50W

11.5V Max. 4.3A

> 0.99

0 - 40ºC

II

1 (Pre Wired)

1 (Pre Wired)

100g

L 73mm x W 36mm x H 25.5mm

Input Voltage

Input Current

Power Range

Output Voltage

Power Factor

Ambient Temperature Range

Insulation Class

Quantity of Input Terminals

Quantity of Output Terminals

Weight

Dimensions

230V a.c. +/- 10% ; 50Hz

0.33A for 70W

70Va: 0 - 70W

11.5V Max. 6.5A

> 0.99

0 - 40ºC

II

1

1 (Pre Wired)

120g

L 118mm x W 36.5mm x H 29.5mm

 

YT105

 

YT150

Input Voltage

Input Current

Power Range

Output Voltage

Power Factor

Ambient Temperature Range

Insulation Class

Quantity of Input Terminals

Quantity of Output Terminals

Weight

Dimensions

230V a.c. +/- 10% ; 50Hz

0.46A for 105W

105Va: 0 - 105W

11.5V Max. 9.3A

> 0.99

0 - 40ºC

II

1

2

140g

L 118mm x W 37mm x H 30mm

Input Voltage

Input Current

Power Range

Output Voltage

Power Factor

Ambient Temperature Range

Insulation Class

Quantity of Input Terminals

Quantity of Output Terminals

Weight

Dimensions

230V a.c. +/- 10% ; 50Hz

0.65A for 150W

150Va: 0 - 150W

11.5V Max. 12.5A

> 0.99

0 - 40ºC

II

2

3

230g

L 160mm x W 53mm x H 32mm

 

YT250

   

Input Voltage

Input Current

Power Range

Output Voltage

Power Factor

Ambient Temperature Range

Insulation Class

Quantity of Input Terminals

Quantity of Output Terminals

Weight

Dimensions

230V a.c. +/- 10% ; 50Hz

1.1A for 250W

250Va: 0 - 250W

11.5V Max. 22A

> 0.99

0 - 40ºC

II

2

3

250g

L 160mm x W 53mm x H 37mm

 

INSTALLATION ADVICE

Each YT Transformer should be located in a well ventilated position. It is important that the cable lengths on the output side of the transformer are neither too short or too long (optimum length - 30cm). If the transformer is fitted too close to the luminaire (nearer than 25cm), heat from the lamp could affect the functioning of the transformer. If the cable is too long, a "voltage drop" may result and it will cause the lamp to be less bright. The longer the cable on the output side, the thicker the cable needs to be to reduce this effect.

DIMENSIONS (Diagrams are not to scale)

YT70 and YT105

YT150

YT250